Stainless Steel Case Pressure Gauges
B132 series
Applications:
Used with the liquid and gas process media not corrosive, not crystallizing and not highly viscous. The glycerin / silicon oil filled type is especially used for measuring points subject to vibration and highly dynamic pressure load. Particularly used in hydraulics, compressors, general mechanical engineering, pumps, water treatment plants, etc.
Technical data:
Dial diameter Ø |
1½”(40mm);2”(50mm);2½”(63mm);3”(75mm);4”(100mm);6”(150mm) |
Case |
Stainless steel 304, IP65
Crimp bezel for dial Ø1½”~ Ø4”; Bayonet bezel for dial Ø2½”~ Ø6” |
Lens |
Acrylic or glass for dial Ø1½”~ Ø4”; Safety glass for dial Ø4” and Ø6” |
Dial |
Aluminum, black and red markings on white background, dial arc 270o |
Measuring principle |
Bourdon Tube, brass
C form tube for ≦70kg/cm2 ; Helical form tube for > 70kg/cm2 |
Movement |
Brass |
Pointer |
Aluminum, black, adjustable pointer available for dial Ø4” and Ø6” |
Connection |
Male thread 1/8”, 1/4”, 3/8”, 1/2”PT(BSPT) / NPT / PF(BSP), brass |
Filling |
Without (dry); glycerin filled; silicon oil filled |
Accuracy |
±2% F.S. for Ø1½” & Ø2”; ±1.5% F.S. for Ø2½”~ Ø6” |
Temperature limits |
Dry: medium +60oC; ambient -20 to + 60oC
Glycerin filled: medium +60oC; ambient + 10 to + 60oC
Silicon oil filled: medium + 60oC; ambient -45 to +60oC
Available for medium +180oC if the bourdon tube is silver soldered. This is special custom-made type upon request. |
Ranges |
Positive 0/1 ~ 0/1000 kg/cm2
Negative 0/-76 cmHg (relative vacuum)
Compound -76cmHg/0/1 ~ -76cmHg/0/20kg/cm2
< other units available, e.g. psi, bar, MPa…etc.> |
Options:
- Safety glass lens for dial Ø2-1/2” & Ø3”
- Blow-out disk by back for dial Ø4”
- Special male or female thread connections
- Cleanness for oxygen, acetylene, hydrogen … etc. dangerous media service
- Restrictor on connection to alleviate pressure pulsation
- Device of red pointer which can leave behind on max. pressure
- Device of diaphragm, electrical contacts or accessories |